Fire Alarm Engineer

Giga EnergyUSAgreenhouseobjavljeno 26. 08. 2026.
Obavezno:HealthTechSecurityPrincipalJuniorRemote

About Giga

Giga is building gigawatts of AI data centers to hasten a future of intelligence and abundance. We build data centers fast and at scale by combining the capabilities of an equipment supplier, engineering firm, general contractor, and real estate developer under one roof. Our team moves quickly and thinks practically. If you're ready to make an impact in an industry that matters, we're looking for people like you.

Why join Giga

The Pace: We're building at a speed most companies talk about but never actually operate at. If you've been bored somewhere else, you won't be here.

The Impact : Every person at Giga touches the work that matters. No layers, no waiting for approval chains. You'll see your fingerprints on what we ship.

The Team: A team of operators defining the future of AI infrastructure. We recruit A-players from the most innovative companies in the world, and they choose Giga because the work here means more.

The Moment : AI doesn't run without power, and that's us. Giga is the picks and shovels behind the AI revolution. This industry is about to explode, and you'll be in the room where it's already happening.

What you'll do

As Fire Alarm Engineer at Giga, you will provide technical design leadership and expertise for fire alarm systems, detection systems, smoke control systems, and life safety systems across our AI data center facilities. You'll work on multiple concurrent projects, ensuring technical excellence, design quality, and code compliance while mentoring junior staff and collaborating closely with project teams, clients, and authorities having jurisdiction. This is a hands-on specialist role for someone who wants real technical ownership and thrives in fast-paced, collaborative environments.

Where you'll work

This role is based in one of our offices (Houston, TX / Long Beach, CA / San Francisco, CA / Reno, NV) or fully remote. We work in person because the best engineering happens when smart people are in the same room. Some travel to active project sites and client meetings should be expected.

That said, we will make exceptions for truly exceptional talent if you live outside one of our hubs. If you're the right person for this role, we'll have a conversation about what works.

Responsibilities

Provide technical design leadership for fire alarm systems, detection systems, smoke control systems, and life safety systems on data center and mission-critical facility projects

Design fire alarm and detection systems using manufacturers' equipment and best practices appropriate for data center facilities

Design detection and monitoring for lithium-ion battery energy storage and UPS battery systems, including off-gas detection, hydrogen monitoring, and thermal runaway response sequences

Develop sequences of operation, equipment schedules, riser diagrams, and device layouts, and prepare and maintain fire alarm specifications

Develop smoke control and management strategies aligned with facility operations and life safety requirements

Perform quality control review of fire alarm and life safety systems drawings, ensuring technical accuracy, code compliance, and alignment with design intent

Provide design guidance and markup comments on other engineers' and designers' submittals, explaining best practices based on real-world data center experience

Ensure design compliance with IBC, IFC, NFPA 1, NFPA 101 Life Safety Code, NFPA 72 Fire Alarm and Signaling Code, NFPA 75, NFPA 76, NFPA 92, NFPA 2001, NFPA 2010, NFPA 13, NFPA 855, and NFPA 70 (NEC), and with FM Global Property Loss Prevention Data Sheets as Owner design criteria

Coordinate fire alarm and life safety system designs with mechanical, electrical, structural, civil, architectural, and fire protection disciplines

Interface with clients, AHJs, and fire alarm contractors to convey and defend design intent, obtain approvals, and resolve technical issues

Support field activities including site observation, acceptance testing with AHJs, and resolution of construction-phase issues

Mentor junior engineers and drafters on fire alarm system design, code requirements, and best practices

Participate in design reviews and quality assurance/quality control efforts across multiple concurrent projects

Requirements

Minimum 5 years of experience designing fire alarm systems

NICET Fire Alarm Systems (FAS) Level III or IV certification

Bachelor's degree in engineering or related field

Experience working on Data Center projects

Extensive knowledge and design experience with fire alarm systems and related manufacturers' equipment, including VESDA aspirating systems, VEWFD spot smoke detectors, and addressable panels

Extensive knowledge and design experience with releasing service and suppression interlocks, including preaction and double-interlock preaction systems, clean agent systems, and generator and battery enclosure interfaces

Extensive knowledge and design experience with lithium-ion battery hazards, including off-gas detection, hydrogen monitoring, and thermal runaway response sequences

Proficiency in IBC, IFC, NFPA 1, NFPA 101 Life Safety Code, NFPA 72 Fire Alarm and Signaling Code, NFPA 75, NFPA 76, NFPA 92, NFPA 2001, NFPA 2010, NFPA 13 and NFPA 855

Knowledge and application of FM Global Property Loss Prevention Data Sheets as Owner design criteria

Knowledge and application of NFPA 70 (NEC), including Article 760, and electrical design requirements for fire alarm and life safety systems

Extensive design experience in data center fire alarm and life safety systems

Field experience with fire alarm system installation, testing, and commissioning, including acceptance testing with AHJs

Proficiency in Revit and AutoCAD to produce complete construction documents — riser diagrams, device layouts, equipment schedules, and sequences of operation — including battery, voltage drop, and NAC and SLC circuit calculations

Proven ability to self-check work, verifying cross-references between sheets, specifications, and sequences of operation, and confirming model numbers against manufacturers' data sheets

Able to work with the Engineer of Record on design direction, incorporate review comments, and coordinate with drafters and other design disciplines

Strong written and verbal communication skills with the ability to explain design decisions to the Engineer of Record, clients, and AHJs

Able to carry multiple concurrent design assignments and deliver on schedule without sacrificing quality

Able to work with minimal day-to-day oversight, make decisions with available information, and move fast in a high-velocity environment

Bonus points

Professional Engineer (PE) license or Engineer-in-Training (EIT) certification

Experience estimating and scheduling mid-to-large-scale projects

Experience in fire protection and plumbing design is a plus.

Familiarity with hyperscale, colocation, and AI-focused data center facility requirements

Texas project experience and familiarity with local AHJ processes

How We Work

We value people who take ownership, raise risks early, communicate directly, and follow through. Incomplete information is part of the job. Make the best decision you can, document it, and adjust as the facts change. Move quickly on reversible decisions and take more care when security, safety, financial, employee, or customer risk is involved.

Benefits

Subsidized health, dental, and vision insurance

Equity (options) in a rapidly growing startup

401(k) with 4% employer match

Unlimited PTO

Parental leave

Healthcare and Dependent Care Flexible Spending Accounts (FSA) or Health Savings Account (HSA)

Commuter benefits, where applicable

Opportunities to collaborate in person at periodic team and company on-sites

Equal Opportunity Employer Statement

Giga Energy is an equal opportunity employer and is committed to fostering an inclusive and diverse workplace. We do not discriminate based on race, color, religion, sex, sexual orientation, gender identity, national origin, age, disability, veteran status, or any other protected characteristic as outlined by federal, state, or local laws. Giga Energy complies with all applicable labor laws, including the California Fair Employment and Housing Act (FEHA) and other relevant state and federal regulations. We provide reasonable accommodations for qualified individuals with disabilities and encourage applicants who require accommodations during the hiring process to contact us.